0-5V / 0-10V / 4-20MA weighing transmitter, high-precision force measuring weight sensor signal amplifier

Other Machines

ISO,CE

EPA4

Farm Tractor

4WD

Gas/Diesel

0 /0

L/C,T/T

Quantity:

Send Enquiry
Product Details

image.png

1.     Technical data

Working voltage: 24VDC

Output signal: 4-20MA

Input signal: sensor sensitivity 2.0MV / V

Output excitation: output excitation voltage 10V (E +)

Operating temperature range: -20-80 

Working environment humidity: 10% RH-90% RH (no condensation)

2.     Connection

Input signal

S+

S-

E+

GND

GNDD

Wire difinetion

Signal +

Signal-

Exaction+

Exaction-

Shielded

Output signal

24V

GND

IO

Vo

GNDD

Wire difinetion

Power+

Power-

Current output

Voltage output

Shielded

3.Gear selection

 

When DIP switch 1 is set to OFF, VO outputs 0-5V,

 When No. 1 is turned ON, VO outputs 0-10V,

When both DIP switches 1 and 2 are turned OFF, VO outputs 0-5V and IO outputs 4-20mA.

 

4.Zero adjustment

 

1: Voltage adjustment First make the system in no-load state, adjust the voltage zero potentiometer (Vzero) to adjust the zero point. Use a multimeter to measure the VO voltage at the output, and make the indication as close to the zero indication as possible.

 

2: Current adjustment First make the system in no-load state, adjust the current zero potentiometer (Izero), use a multimeter current block to measure the output current IO, try to make it close to 4mA.

 

 5.Gain adjustment

 

1: Voltage full-scale adjustment loads the system with a certain weight value (recommended range: 80% ~ 100% FS), calculates the output voltage value according to the proportional relationship between the loaded weight and the maximum weighing value, monitors the output with a digital multimeter, and rotates the voltage to full Vspan adjusts the full scale output.

 

2: Current full-scale adjustment loads the system with a certain weight value (recommended range: 80% ~ 100% FS), calculates the output current value according to the proportional relationship between the loaded weight and the maximum weighing value, monitors the output with a digital multimeter, and rotates the current full Adjust the full scale output (Ispan) as close as possible to 20mA.

 

6.Review

 

Make the system in no-load state and measure the zero output; load a certain weight value and measure whether the output voltage meets the expected magnification. If it does not match, please adjust again.